Dec 172013
 

Click To View Specifications (PDF Format)

5 WAY MANIFOLD
36. 5 WAY MANIFOLD VALVE FLAT TYPE 37. 5 WAY MANIFOLD VALVE T TYPE
3 WAY MANIFOLD
35. 3 WAY MANIFOLD H TYPE 34. 3 WAY MANIFOLD VALVE T TYPE 33. 3 WAY MANIFOLD VALVE
2 WAY MANIFOLD
31. 2 WAY MANIFOLD BLOCK AND BLEED TYPE 30. 2 WAY MANIFOLD VALVE T TYPE 29.a. 2 WAY MANIFOLD VALVE WITH 0.5 PLUG 29. 2 WAY MANIFOLD VALVE

 

INLET OUTLET
½” NPT (F) Flanged

Three valves manifolds : For line or remote installation- Flat Type

'Flat' Type
‘Flat’ Type
INLET OUTLET
½” NPT Female ½” NPT Female

Three valves manifolds : For direct mounting – ‘H’ Type

'H' Type
‘H’ Type
INLET OUTLET
Flanged Flanged

Five Valves Manifolds

'Flat' Type 'Flat' Type  Manifolds
‘Flat’ Type ‘T’ Type

Five valves manifolds : For Remote Mounting – Flat Type

'Flat' Type
‘Flat’ Type
INLET OUTLET
½” NPT Female ½” NPT Female

Five valves manifolds : For Direct Mounting – ‘T’ Type

'T' Type
‘T’ Type
INLET OUTLET DRAIN/TEST
½” NPT Female Flanged ½” NPT Female

Purpose : Two valve manifolds combine facilities for isolation, calibration test and venting of instrument. By incorporating all these functions in one block, considerable material & installation cost saving will be achieved. The manifold is for use with pressure guages, transmitters, pressure switches & similar pressure measurement equipment. The manifold is available in number of configuration to suit every type of installation. Port connections are standard in NPT and BSP taper. A variety of manifold mounting/support methods are possible. Click To View Specifications (PDF Format)Purpose : Three valve manifolds are used in conjunction with differential pressure transmitters, combine instrument isolation & equalising in one block resulting in lower installation cost. The manifold designs have facilities for direct mounting to differential pressure transmitter or remote mounting for transmitters. Most design incorporate base mounting hole, mounting brackets blocks are also available.Click To View Specifications (PDF Format)Description : This manifold is suitable for direct mounting to a differential pressure transmitter which has inlet and flanged tapped hole on 54mm (2 1/8″) centres. Optional upstream or downstream test ports are available. Manifolds are supplied with 2 nos & 4 nos PTFE ‘O’ rings for manifolds to instrument ceiling & 4 off 7/16″ UNF high tensile zinc plated carbon steel bolts.  Click To View Specifications (PDF Format)Description : This manifold is design for remote mounting from differential pressure transmitter. This is made possible by including threaded outlet connections which are 54mm (2 1/8″) centres to suit inlet centre connections of the instrument. The manifold provides two instrument isolating valves and one equalising valve for instrument zeroing. Base mounting holes are provided and suitable for M 10 X 1.5 bolts.  Click To View Specifications (PDF Format)Description : H – Type three valve manifolds are in conjuction with differential transmitter and integral orifice assembly. They combine instrument isolation & equalisation in one block resulting in lower installation costs. The manifold design have facilities for mounting to differential pressure and integral orifice assemblyClick To View Specifications (PDF Format)Purpose : Five valve manifolds are used in combination with differential pressure transmitters providing isolations, equalising and drain/test function. The manifold allows the operator to isolate, zero adjust the instrument & safety drain any trap medium. The drain ports have dual functions. They can also be used as test or calibration connections after the drawing operation has been completed. Manifold design covers both & remote installations.Click To View Specifications (PDF Format)Description : The manifold is designed for remote mounting from the differential pressure transmitter. This is made possible by including threaded outlet connections which are on 54mm (2 1/8″) centres to suit the inlet connections on the instrument. The manifold provides two instrument isolating valves, one equalising valve for zeroing and two drain/test facilities. Click To View Specifications (PDF Format)Description : This manifold is suitable for direct mounting to a differential pressure transmitter which has the inlet and flange tap holes on 54mm ( 2 1/8″ ) centres. The manifolds are supplied with 2 off P.T.F.E. manifold to instrument sealing rings & 4 off 7 1/16″ UNF high tensile zinc plated carbon steel bolt.